Chevrolet · 2024–2026
Equinox EV 3RS AWD
Sporty all-wheel drive. Here's what its onboard charger actually needs from your home's electrical panel.

Home (Level 2) charging facts
Pulled straight from the Equinox EV 3RS AWD's onboard charger rating - not a generic EV number.
- Onboard charger draw
- 11.5 kW
- ~48A at 240V (kW × 1000 ÷ 240)
- Empty-to-full at max Level 2
- 7.4 hrs
- 85 kWh battery ÷ 11.5 kW
- Range added per hour
- ~36 mi/hr
- 11.5 kW × 3.1 mi/kWh efficiency
- DC fast charging
- 150 kW max
- Public chargers only - tapers as the battery fills
Typical full-speed install
48A charger on a 60A circuit
Reaches this car's 11.5 kW ceiling. Whether your panel has room for that circuit depends on everything else already on it - that's the actual assessment.
Connector
CCS
CCS (Combined Charging System) is the most common connector on non-Tesla EVs for both home Level 2 charging and public DC fast charging.
On the Equinox EV 3RS AWD specifically, that connector carries up to 11.5 kW at home on Level 2 and up to 150 kW on public DC fast hardware.
Charging speed by circuit size
The Chevrolet Equinox EV's onboard charger can't use more than 11.5 kW AC no matter how big the circuit - past 48A, a bigger charger buys you nothing on this car.
| Charger setting | This car actually draws | Range added / hour | 8-hr overnight |
|---|---|---|---|
| 16A | 3.8 kW | ~12 mi | ~96 mi |
| 24A | 5.8 kW | ~18 mi | ~144 mi |
| 32A | 7.7 kW | ~24 mi | ~192 mi |
| 40A | 9.6 kW | ~30 mi | ~240 mi |
| 48A | 11.5 kWcapped by car | ~36 mi | ~288 mi |
Overnight, at full onboard speed
288 mi / 8 hrs
360 mi across a 10-hour window, at 11.5 kW.
Approximate cost to fill from empty
$11.05
Assumes $0.13/kWh (a national-average estimate, not your local rate) × 85 kWh - about $0.042/mile.
Chevrolet Equinox EV charging questions
How long does it take to charge a 2024–2026 Chevrolet Equinox EV 3RS AWD on a Level 2 charger?
About 7.4 hours from empty to full at its 11.5 kW onboard-charger ceiling (85 kWh battery ÷ 11.5 kW).
Times scale with amperage - see the circuit-size table above for other settings.
What amperage does a Chevrolet Equinox EV draw on Level 2?
At its full 11.5 kW rate, the Chevrolet Equinox EV draws about 48A at 240V (kW × 1000 ÷ 240 = amps).
Can a Chevrolet Equinox EV use a 48-amp charger?
Not to any real benefit. The Chevrolet Equinox EV's onboard charger tops out at 11.5 kW (~48A) - a 48A charger doesn't charge it any faster than one already sized to 48A.
How much range does a Chevrolet Equinox EV add per hour on a Level 2 charger?
About 36 miles of range per hour at its 11.5 kW ceiling (11.5 kW × 3.1 mi/kWh efficiency).
How much range does an 8-hour overnight charge add to a Chevrolet Equinox EV?
Roughly 288 miles from an 8-hour overnight charge (36 mi/hr × 8 hours), or about 360 miles across a 10-hour window.
What's the DC fast charging ceiling for a Chevrolet Equinox EV?
Up to 150 kW on a public DC fast charger - well above its 11.5 kW Level 2 (home) ceiling, though DC fast rates taper as the battery fills.
Other Chevrolet EVs
Will your panel handle this?
ChargeRight runs the full NEC load calculation against your actual panel - not a generic rule of thumb.
Check my panel$49.99 - results in minutes