Genesis · 2024–2025
Electrified GV70 Advanced AWD
800V architecture enables ultra-fast DC charging. 10.5kW onboard charger — 48A Level 2 charger is ideal. Here's what its onboard charger actually needs from your home's electrical panel.

Home (Level 2) charging facts
Pulled straight from the Electrified GV70 Advanced AWD's onboard charger rating - not a generic EV number.
- Onboard charger draw
- 10.5 kW
- ~44A at 240V (kW × 1000 ÷ 240)
- Empty-to-full at max Level 2
- 7.4 hrs
- 77.4 kWh battery ÷ 10.5 kW
- Range added per hour
- ~32 mi/hr
- 10.5 kW × 3.05 mi/kWh efficiency
- DC fast charging
- 350 kW max
- Public chargers only - tapers as the battery fills
Typical full-speed install
48A charger on a 60A circuit
Reaches this car's 10.5 kW ceiling. Whether your panel has room for that circuit depends on everything else already on it - that's the actual assessment.
Connector
CCS
CCS (Combined Charging System) is the most common connector on non-Tesla EVs for both home Level 2 charging and public DC fast charging.
On the Electrified GV70 Advanced AWD specifically, that connector carries up to 10.5 kW at home on Level 2 and up to 350 kW on public DC fast hardware.
Charging speed by circuit size
The Genesis Electrified GV70's onboard charger can't use more than 10.5 kW AC no matter how big the circuit - past 48A, a bigger charger buys you nothing on this car.
| Charger setting | This car actually draws | Range added / hour | 8-hr overnight |
|---|---|---|---|
| 16A | 3.8 kW | ~12 mi | ~96 mi |
| 24A | 5.8 kW | ~18 mi | ~144 mi |
| 32A | 7.7 kW | ~23 mi | ~184 mi |
| 40A | 9.6 kW | ~29 mi | ~232 mi |
| 48A | 10.5 kWcapped by car | ~32 mi | ~256 mi |
Overnight, at full onboard speed
256 mi / 8 hrs
320 mi across a 10-hour window, at 10.5 kW.
Approximate cost to fill from empty
$10.06
Assumes $0.13/kWh (a national-average estimate, not your local rate) × 77.4 kWh - about $0.043/mile.
Genesis Electrified GV70 charging questions
How long does it take to charge a 2024–2025 Genesis Electrified GV70 Advanced AWD on a Level 2 charger?
About 7.4 hours from empty to full at its 10.5 kW onboard-charger ceiling (77.4 kWh battery ÷ 10.5 kW).
Times scale with amperage - see the circuit-size table above for other settings.
What amperage does a Genesis Electrified GV70 draw on Level 2?
At its full 10.5 kW rate, the Genesis Electrified GV70 draws about 44A at 240V (kW × 1000 ÷ 240 = amps).
Can a Genesis Electrified GV70 use a 48-amp charger?
Not to any real benefit. The Genesis Electrified GV70's onboard charger tops out at 10.5 kW (~44A) - a 48A charger doesn't charge it any faster than one already sized to 44A.
How much range does a Genesis Electrified GV70 add per hour on a Level 2 charger?
About 32 miles of range per hour at its 10.5 kW ceiling (10.5 kW × 3.05 mi/kWh efficiency).
How much range does an 8-hour overnight charge add to a Genesis Electrified GV70?
Roughly 256 miles from an 8-hour overnight charge (32 mi/hr × 8 hours), or about 320 miles across a 10-hour window.
What's the DC fast charging ceiling for a Genesis Electrified GV70?
Up to 350 kW on a public DC fast charger - well above its 10.5 kW Level 2 (home) ceiling, though DC fast rates taper as the battery fills.
Other Genesis EVs
Will your panel handle this?
ChargeRight runs the full NEC load calculation against your actual panel - not a generic rule of thumb.
Check my panel$49.99 - results in minutes